EMX Multi-Voltage Vehicle Loop Detector | EMX-ULT-MVP-U
The ULTRA-MVP multi-voltage vehicle loop detector combines small size with a 12VDC to 240VAC input range. Reduce inventory costs by stocking and transporting just one universal unit.
This detector features DETECT-ON-STOP or (DOS) technology, which allows detection only when a vehicle has come to a complete stop on the loop. This exclusive feature is unique to EMX and is a major advantage if you want to ignore cross traffic in tight spaces.
The ULT-MVP provides two relay outputs – one for indicating vehicle presence and a second for loop fault or pulse on entry/pulse on exit, or DETECT-ON-STOP.
Features
- Ignores cross traffic in tight spaces with DETECT-ON-STOP feature
- Fits into small operator housings, saving space
- Easy to install and setup with the ULTRAMETER sensitivity display
- Easy identification of interference problems using the crosstalk and RFI
- 10 sensitivity settings
- 4 operating frequencies
- Automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite or normal (5 min.) presence
- Small size: 73 x 38 x 78mm
- Socket mount -11 pin (JEDEC B11-88)
- CE compliant
Manufacturer’s Warranty
- 2 Years
Technical Specifications
- Sensitivity: 10 levels, 0-9
- Ultra METER display: Indicates optimum sensitivity level, 0-9 diagnostic aid
- Loop frequency: 4 settings (low, med-low, med-hi, high)
- Loop inductance: 20…2000µH (Q factor > 5)
- Grounded loop: Isolation transformer allows operation with poor quality loops
- Automatic tuning: Detector tunes to loop on power-up and following frequency count function
- Environmental tracking: Automatic compensation
- Surge protection: Loop circuitry protected by surge suppressors
- Presence relay: SPDT relay contacts (form C)
- Output B relay: SPDT relay contacts (form C)
- Contact rating (resistive load): 2A @ 30VDC, 0.5A @ 125VAC
- Power / loop fault indicator: Green LED
- Detect / frequency count indicator: Red LED
- Detect-on-Stop: Requires vehicle to stop for a minimum of 1 second (1-2s typical)
- ASB (Automatic Sensitivity Boost): Increases sensitivity after initial detection to prevent dropout due to high-bed vehicles
- Power: 12…60 VDC (Max. 0.8 VA) 12…240 VAC (48…62Hz) (Max. 1.4 VA)
- Operating current: 20mA standby / 50mA detect
- Operating temperature: -40°C…82°C (-40°F…180°F) 0…95% relative humidity
- Dimensions (L x W x H): 73mm (2.9”) x 38mm (1.2”) x 78mm (3.1”)
- Weight: 0.25 lbs. (113 g)
- Housing: ABS plastic, IP30
- Connector: Socket mount – 11 pin male (JEDEC B11-88)